IK08 vs IK10: Which Impact Rating Fits Truck and Trailer Lights
IK10 withstands four times the impact energy of IK08: 20 joules against 5 joules. IK08 is enough where a light is mounted out of the way and rarely struck. IK10 is the safer specification where a light sits low, near loading equipment or in reach of anyone who walks past. For trucks and trailers, the rating is only half the decision. A lamp also has to keep water out, stay on its mount and meet DOT lighting rules, and we build and sell our lighting with those demands in mind.
TL;DR
- IK08 means 5 joules of impact energy (a 1.7 kg mass dropped 300 mm). IK10 means 20 joules (a 5 kg mass dropped 400 mm).
- IK is about impact. IP is about dust and water. A truck light needs to be judged on both.
- Check which part of the lamp the IK rating covers: lens, housing or the whole assembly with its mount.
- Conformal coating and potting are two ways to protect the circuit board inside a light. Coating is thin and repairable, potting is a solid fill.
- Low-mounted, yard-level and dock-side lights are where the step up to IK10 matters most.
Table of Contents
- What an IK rating actually tells you
- IK08 vs IK10 side by side
- IK versus IP: two different questions
- When IK08 is enough and when to step up to IK10
- What the IK number does not cover
- Conformal coating vs potting: how the circuit inside is protected
- How to choose for your fleet
- Where our lighting fits
- FAQ
- Sources
What an IK rating actually tells you
An IK rating is a two-digit code that states how much mechanical impact an enclosure can take without losing the protection it was designed to give. The scale is defined in the IEC 62262 standard. According to Megalab’s IEC 62262 testing page, it runs from IK00 (no protection) to IK10 (20 J). A 2021 amendment to the standard added an IK11 level, but IK10 is the top rating you will see on most lighting specs.
The test is simple in principle. A hammer of defined mass and face shape strikes the surfaces that are exposed once the product is installed. The sample is mounted the way it would be in service. Spring-operated hammers cover IK01 to IK06. A pendulum or a vertical free-falling hammer covers IK07 and above. Afterward the product is inspected against the pass criteria of its own product standard.
Passing does not mean the product looks untouched. Per The Enclosure Company’s guide, an enclosure passes if it still protects live parts, keeps its IP rating and its door or lid still works. Dents, scratches and finish cracks are allowed. The rating is about whether the product still does its job.

IK08 vs IK10 side by side
UL’s IK and IP testing guide for lighting products lists the energy for each level. Here is the part of the scale you will meet when you compare lights:
| Rating | Impact energy | Roughly equal to |
|---|---|---|
| IK06 | 1 J | Light knock |
| IK07 | 2 J | A small tool bumped against it |
| IK08 | 5 J | 1.7 kg dropped from 300 mm |
| IK09 | 10 J | Heavier, repeated contact |
| IK10 | 20 J | 5 kg dropped from 400 mm |
The drop heights and masses for IK08 and IK10 are confirmed by APEM’s explanation of the IK scale. The IK06 figure comes from UL’s table, and the IK07 figure from Megalab’s page.
The jump from IK08 to IK10 is a fourfold increase in energy, not a small step. IK08 is common for commercial lighting and indoor enclosures. IK10 is specified where deliberate or heavy contact is realistic: parking structures, sports facilities and street furniture, according to Megalab.

What the numbers feel like in a truck yard
A 5 joule hit is roughly a dropped wrench or a thrown piece of gravel at close range. A 20 joule hit is a heavy tool swung or dropped, a pallet corner nudged by a forklift, or a strap buckle whipped against a fixture. Those are everyday events at a dock door, on a flatbed deck or at the rear of a trailer being backed into a loading bay.
The ratings do not simulate a collision. The IET’s guidance on IK codes notes that IK10 does not make an enclosure immune to vehicle impact. It describes using bollards, plinths or kerbs to reduce that risk. On a truck, the equivalent is placement and guarding, not just a higher number.
IK versus IP: two different questions
IK answers “what happens if it is hit?” IP answers “what gets inside?” The two codes are separate. UL’s guide explains that IP ratings classify protection against solid objects (first digit) and water (second digit). For example, IP66 is dust-tight and protected against powerful water jets.
The IET warns that an enclosure rated IK10 without a sufficient IP code could still be prone to water ingress. Reverse it and the point holds: a lamp that keeps out a pressure washer but cracks on its first knock will not stay sealed for long. A truck or trailer light lives in spray, road salt and vibration, so you want both numbers on the spec sheet.
If you are choosing on the water side, our guides on IP67 vs IP69K lights and on choosing the right IP rating for trailer lights go through the ingress side in the same detail.
When IK08 is enough and when to step up to IK10
Specifiers split the choice by exposure, not by the product category. The pattern in industry guidance is consistent:
- IK08 suits workshops, warehouses and loading bays that are not open to the public, and fixtures mounted high enough to stay clear of traffic.
- IK09 sits between the two, listed for industrial, loading and outdoor areas.
- IK10 is the usual specification for anything the public or moving equipment can reach, including street furniture, transport hubs and places where vehicles pass close by.
Megalab’s page and The Enclosure Company’s guide agree on that broad split.
Translated for the vehicles our customers run:
- Rear-mounted tail, stop and turn lights on trailers get hit at docks, by hitches, by loading ramps and by debris. These are the lights where more impact margin pays off.
- Side markers and clearance lights are low-energy exposure on most trailers but sit along the full length of the body. Brushes against posts, branches and bay doors are the usual damage.
- Cab roof and top marker lights are high on the vehicle, away from dock traffic, though exposed to low branches and car-wash brushes.
- Work lamps and strobes on tow trucks, service trucks and construction vehicles are used where tools, chains and equipment move constantly.
- Fender and pedestal lights sit low and close to tires, so they take spray and flung stones along with contact.
A mounting-height rule used in industrial lighting is a handy cross-check: fixtures well above head height can sit at the lower rating, while anything low or near moving equipment should go higher. For truck gear, the rear of a trailer is the “low and near equipment” case.
What the IK number does not cover
IK is one line on a spec sheet. These are the points that decide whether a light survives a hard season.
The part that was tested
The IET advises confirming which parts of the enclosure were verified: hinges, locks, fixings, brackets, cable entries and doors. An enclosure can carry different IK codes depending on the part, the angle or the side that was struck. A rating on the lens alone says less than a rating on the finished lamp with its bezel and mounting. When you compare two lights, make sure both ratings describe the same thing.
Internals and mounts
An IK pass means the enclosure still provides its rated IP level, no live parts are accessible and safety functions remain intact. It does not describe shock to the LED driver, solder joints or the strength of the mounting bracket, and a glancing blow can shear a fixture off its mount. This is why mounting, grommets, plugs and wiring deserve as much attention as the lens.
Lens material
Impact behavior depends heavily on what the lens is made of. Our guide on polycarbonate vs acrylic lenses on a truck covers how the two materials hold up on the road.
Weather, vibration and heat
Corrosion, UV, vibration and temperature swings are separate from impact. A good truck-light specification lists them next to IK and IP, then adds the DOT requirements that apply to your lamp positions. Our U.S. fleet checklist for DOT lighting walks through those before an inspection.
Conformal coating vs potting: how the circuit inside is protected
The same shock and moisture that an IK and IP rating address from the outside also reach the circuit board inside a light. Two methods protect it, and they suit different jobs.
Conformal coating is a thin insulating layer, typically 25 to 75 µm, applied by spray, dip or brush. According to Littelfuse’s application note, it shields a board from moisture, dust and chemicals while keeping the assembly light and easy to inspect and repair.
Potting fills the board or chosen components in resin. The same note describes a barrier against mechanical stress, vibration and extreme environments, with excellent electrical insulation. The trade-off is weight, size, cost and difficulty of repair.
| Conformal coating | Potting | |
|---|---|---|
| Thickness | Thin film | Bulk fill |
| Best against | Moisture, dust, condensation | Shock, vibration, immersion, temperature extremes |
| Weight | Minimal | Added |
| Inspection and repair | Easier | Difficult |
Riverside Integrated Solutions describes spray-on silicone coating as a simple first line against moisture and corrosion. It reserves full potting for electronics that face extremes, such as hot sun, dust, chemicals and high-pressure washdown.
The two methods work alongside an IK rating, not in place of it. The enclosure is the first barrier against impact and water. Coating or potting is the layer behind it. Neither one changes what the housing itself can take from a 20 joule strike.
How to choose for your fleet
Work through these questions in order:
- Where does the light mount? Low and near docks, ramps and tow gear points toward IK10. High and out of reach can work at IK08.
- What hits it? Gravel and brushes are light duty. Tools, chains and equipment edges are heavier.
- What is the IP rating? Set the water requirement separately, then confirm the impact rating on top.
- What does the rating cover? Lens, housing, or the complete lamp with its mounting.
- Is it DOT-compliant for the position? The legal requirement is not optional, whatever the impact number says.
- Is it serviceable? If you replace lamps as part of routine maintenance, consider how the lamp is mounted and sealed: grommets and plugs matter for both fit and water resistance.
The IET’s advice to keep inspecting installed enclosures for impact damage, wear and loose mounting applies to lamps too. Put a visual check of lenses, grommets and mounts into your pre-trip routine.
Where our lighting fits
We sell DOT-compliant LED lighting, wiring, reflective tape and grommets and plugs for trucks, trailers and commercial vehicles. Our products use leak-proof housings and high-intensity reflectors, and the range is built for harsh weather and long hauls. Many listings carry waterproof ratings you can compare directly, such as IP67 on our red, white and amber 6-inch oval LED trailer light kit with grommets and plugs and IP68 on our 12V submersible LED trailer light wiring kit.
For rear-of-trailer duty, our 42 LED rectangle trailer tail light kit is listed as DOT FMVSS 108 and submersible, and it ships with grommets and plugs. For service and tow work, the amber strobe work lamp is listed as waterproof, dustproof and anti-shock.
Browse the full range on our collections page, or go straight to wiring and grommets and plugs to finish the installation.

Our point of view
Fleet managers rarely lose a light to one dramatic event. They lose it to a slow run of knocks, spray, salt, vibration and loose connections. That is why we look at a truck light as a system: lens, housing, seal, reflector, wiring, grommet and plug.
An IK number is a useful way to compare impact margin, and the step from IK08 to IK10 is a real fourfold increase. But the rating sits next to waterproofing, DOT compliance and mounting. A lamp that meets all of them stays visible, and visibility is the whole job of a lamp on a trailer at night.
That is the thinking behind our range. We use leak-proof housings, high-intensity reflectors and thicker copper wiring, and we build to exceed DOT standards for long hauls and harsh conditions. Over 1,000,000 drivers rely on our components daily, and we want your next lamp, harness or roll of tape to be one you stop thinking about.
All
FAQ
What is the difference between IK08 and IK10?
IK08 covers an impact of 5 joules, equal to a 1.7 kg mass dropped from 300 mm. IK10 covers 20 joules, equal to a 5 kg mass dropped from 400 mm. That makes IK10 four times the impact energy of IK08.
Is IK10 always better than IK08 for truck lights?
IK10 gives the most impact margin, so it is the stronger choice for low-mounted lights and for lights near docks, ramps and equipment. A high-mounted light that is seldom touched may be well served at IK08. Whatever the number, check that it applies to the complete lamp and pair it with a suitable IP rating.
Is an IK rating the same as an IP rating?
No. IK measures resistance to mechanical impact, while IP measures protection against solids such as dust and against water. A truck light needs a suitable value for both, because a tough housing that lets water in will still fail.
Should I use conformal coating or potting on light electronics?
Conformal coating is a thin, light layer that suits moisture, dust and condensation and leaves the board easy to inspect and repair. Potting is a solid resin fill used where shock, vibration, immersion or extreme temperatures are expected, at the cost of weight and repairability. Many designs use a sealed enclosure first, with coating as a second layer.
What do IK06 and IK09 mean?
Per UL’s table, IK06 is 1 joule and IK09 is 10 joules. IK09 sits halfway between IK08 and IK10 and is commonly listed for industrial, loading and outdoor areas.
Sources
- IK Rating Testing to IEC 62262, Megalab
- IK & IP Testing for Lighting Products, UL
- IK ratings explained, The Enclosure Company
- IK rating and IK test standards, APEM
- IK Ratings Explained: Understanding Enclosure Impact Protection, IET Wiring Matters
- Protection of Electronic Components on Printed Circuit Boards, Littelfuse
- Conformal Coating vs. Potting, Riverside Integrated Solutions